Uploaded image for project: 'Couchbase Java Client'
  1. Couchbase Java Client
  2. JCBC-207

incorrect logic in reconnection threshold leads to never actually reconnecting

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 1.1.0
    • Component/s: None
    • Security Level: Public
    • Labels:
      None

      Description

      In the CouchbaseConnectionFactory, the pastReconnThreshold() method doesn't correctly check the threshold time. It's using millis mixed with nanos.

        Issue Links

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

          ingenthr Matt Ingenthron created issue -
          ingenthr Matt Ingenthron made changes -
          Field Original Value New Value
          Assignee Michael Nitschinger [ daschl ] Matt Ingenthron [ ingenthr ]
          ingenthr Matt Ingenthron made changes -
          Link This issue depends on SPY-108 [ SPY-108 ]
          daschl Michael Nitschinger made changes -
          Status Open [ 1 ] Closed [ 6 ]
          Fix Version/s 1.1.0 [ 10274 ]
          Resolution Fixed [ 1 ]
          ingenthr Matt Ingenthron made changes -
          Workflow jira [ 23543 ] Couchbase SDK Workflow [ 38489 ]

            People

            • Assignee:
              ingenthr Matt Ingenthron
              Reporter:
              ingenthr Matt Ingenthron
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Gerrit Reviews

                There are no open Gerrit changes