    Description

      1. Create XDCR - unidirectional
      2. Add some mutations and record vb_uuid and seq no
      3. Kill memcached process at remote end
      4. Check vb_uuid, it remains same after remote server crash

      [2016-05-15 07:48:02,467] - [checkpointXDCR:422] INFO - vb_uuid before crash :25933187435822, after crash : 25933187435822
      FAIL
      

      This is a regression. similar issue was verified for 3.0 - MB-11085