Details
-
Bug
-
Resolution: Not a Bug
-
Major
-
None
-
7.0.0
-
Build: 5302
-
Untriaged
-
-
1
-
Unknown
Description
This testing was done in CND framework with 7.0.0-5302
Steps:
- Created a 5 node Cluster.
- Killed 2 nodes of the cluster (test-couchbase-ndllr-0000.test-couchbase-ndllr.test-dhkzh.svc and test-couchbase-ndllr-0001.test-couchbase-ndllr.test-dhkzh.svc).
- The Operator does a forced failover following which the 2 nodes mentioned above are evicted. (Failover report attached: failover-0-1.json)
- 2 new nodes are created to maintain the cluster configuration and are rebalanced in. (Rebalance Report attached: rebalanceReport-7.0.0.json)
Expectations as per 6.6.2:
- Force failed nodes are left in the inactive failed state (screenshot attached named: 6.6.2-1 and 6.6.2-2).
Observation in 7.0.0:
- Force failed nodes are evicted. (screenshot attached named: 7.0.0-1, 7.0.0-2 and 7.0.0-3).
Q: Is this behaviour expected in 7.0.0 ?
Operator logs attached (cbopinfo)
Cluster Logs links attached.
CC: Simon Murray
Attachments
Issue Links
- relates to
-
K8S-2319 Work Around CBS7 Behavioural Changes
- Closed