Description
With backfill pipeline, throughSeqnoTrackerSvc implemented a bg scanner to go scan for throughSeqno to make sure the throughSeqno has been processed before stopping the pipeline.
However, if the pipeline is stopped/restarted before this process finishes, the bg scanner will keep not know and will keep running up to a maximum of 5 * 300 sec == 25 minutes.
If a lot of backfill pipeline restart happens, then there will be a lot of these stray bg processes running periodically eating up valuable resources.
Attachments
Issue Links
- is a backport of
-
MB-47897 XDCR - throughSeqnoTracker bg scanner may run for a long time
- Closed
For Gerrit Dashboard: MB-47900 | ||||||
---|---|---|---|---|---|---|
# | Subject | Branch | Project | Status | CR | V |
159710,1 | MB-47900 - stop throughSeqnoTracker bg scanning process when backfill pipeline is stopped | master | goxdcr | Status: ABANDONED | 0 | 0 |
159711,2 | MB-47900 - stop throughSeqnoTracker bg scanning process when backfill pipeline is stopped | cheshire-cat | goxdcr | Status: MERGED | +2 | +1 |