Details
-
Bug
-
Resolution: Fixed
-
Critical
-
7.1.0
-
Enterprise Edition 7.1.0 build 1787
-
Untriaged
-
-
1
-
Unknown
Description
Build: 7.1.0-1787
Scenario:
- 7 node cluster
- Couchbase bucket with replicas=3
- Set auto-failover with max_events=1 and timeout=5
- Stop memcached on 2 nodesĀ (172.23.100.13 and 172.23.100.14)
Observation:
Seeing auto-failover is getting triggered and fails with the following reason and getting retied continuously.
Could not auto-failover more nodes (['ns_1@172.23.100.14']). Maximum number of auto-failover events (1) has been reached
|
Expected behavior:
Auto-failover should never get attempted if the max_events configured is less than the failed nodes in cluster.