Uploaded image for project: 'Couchbase .NET client library'
  1. Couchbase .NET client library
  2. NCBC-3740

In Faster Failover mode, NotMyVBucket always result in a GetClusterMap request.

    XMLWordPrintable

Details

    • Bug
    • Resolution: Fixed
    • Major
    • 3.5.1
    • None
    • None
    • None
    • 1
    • SDK12: Scp Fnc, FIT, Misc

    Description

      Prior to Faster Failover, NotMyVBucket responses would trigger an immediate re-fetch of the bucketconfig.

       

      When Faster Failover is available, the logic should be

       

      1. If the response contains a new BucketConfig, use that.
      2. Otherwise, treat the NMVB as a notice that the current config is out of date, just as if we got a config push.

      Attachments

        Activity

          People

            richard.ponton Richard Ponton
            richard.ponton Richard Ponton
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: