Uploaded image for project: 'Couchbase Documentation'
  1. Couchbase Documentation
  2. DOC-11438

Requesting the information to be added that is described in the description to the Sync gateway documentation

    XMLWordPrintable

Details

    • Task
    • Resolution: Unresolved
    • Major
    • None
    • None
    • sync-gateway
    • None
    • production
    • 0

    Description

      Background:

      • Customer created a bucket A with the durability level as persistenttomajority.
      • Customer is using this A bucket in the Sync gateway configuration.
      • Using this A bucket in the sync gateway is causing the errors while syncing the documents from CouchbaseLite to the sync gateway with the below error.

      Error syncing document with id: 06c7b8f6-a2ea-47af-86ff-680d39eba598, Internal error: The requested key has a pending synchronous write (SyncWriteInProgress)

      Description:

      We could see that Sync Gateway does not support non-default durability settings.

      But we were not able to find this information in the sync gateway documentation, so we would like to request that you add this information to the document.

      Please find the CBSE related to this at https://issues.couchbase.com/browse/CBSE-14999.

      The customer was referring to this information in the sync gateway documents but was not able to find it.