Uploaded image for project: 'Couchbase Server'
  1. Couchbase Server
  2. MB-2501

data lost in membase bucket when click fail over

    XMLWordPrintable

Details

    • Bug
    • Resolution: Fixed
    • 1.6.0 GA
    • 1.6.0 beta4
    • ns_server
    • None
    • Operating System: Ubuntu 9.x
      Platform: X64

    Description

      Created an attachment (id=787)
      diag of node A

      Install ms 1.6.0beta4-83 64bit on 2 ubuntu 9.04 64bit standalone servers.
      At node A, create 4 buckets (2 memcached and 2 membase).
      Load data to all buckets.
      Get data back at all buckets. Work as expected.
      Run a load on node A.
      During load running, at node A, add node B to node A.
      Rebalance.
      Get data back at all buckets. Work as expected.
      Shutdown node B. Click fail over and not rebance yet.
      Get data back from memcached buckets. Work as expected.
      Get data back from membase buckets. Data lost about 50%
      http://screencast.com/t/uTHt3Qzqo
      http://screencast.com/t/bhcFSRYeYaC
      http://screencast.com/t/sHUoQrbMl

      Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

        Activity

          People

            sean@northscale.com Sean Lynch (Inactive)
            thuan@northscale.com thuan@northscale.com
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue