Uploaded image for project: 'Couchbase Server'
  1. Couchbase Server
  2. MB-3200

Couchbase server doesn't handle wall-clock time changes

    XMLWordPrintable

Details

    • Untriaged
    • Release Note

    Description

      Steps to reproduce:

      • set up single node cluster
      • set time 2 hours back
      • load data in membase
      • observe that nothing is getting persisted to disk
      • set time 2 hours forward
      • observe that is started persisting data

      Accoring to Dustin, ep-engine's dispatcher uses pthread_cond_timedwait which uses absolute value of wall-clock time. POSIX allows to configure waiting using monotonic clock, but that feature is optional.

      The proposal for now is to avoid large wall-clock changes. Users should run ntpd to keep node's time in sync, but membase service should be started after initial clock synchronization is done.