Description
Int64 support was added as part of MB-20385. This changed the encoding format of the integers. This is a problem as after upgrade the storage is going to have a mix of old format and new format.
For scans, we convert the low/high key to storage format and do the comparison. This would only work with newly added storage keys. The old storage entries won't match due to different format.
Attachments
Issue Links
For Gerrit Dashboard: MB-29157 | ||||||
---|---|---|---|---|---|---|
# | Subject | Branch | Project | Status | CR | V |
92580,2 | MB-29157 Revert to old encoding format for int | spock | indexing | Status: MERGED | +2 | +1 |
92581,3 | MB-29157 Add collatejson method to fix encoding format | spock | indexing | Status: MERGED | +2 | +1 |
92587,2 | MB-29157 Add Version information to Projector | spock | indexing | Status: MERGED | +2 | +1 |
92588,2 | MB-29157 Fix key encoding based on projector version | spock | indexing | Status: MERGED | +2 | +1 |